1) Chambers passing CR test

Chamber passed CR test this week:  EMS5A02, EML4A07, EML4A01

Total number of chamber passed CR test at CERN:   15

2) Chambers in progress 

EML3A15: Taking CR data. 

EML3C07: ready for CR data taking.

EMS4C16: Top multilayer re-certified. cabling done, T sensors and
inplane system tested. HV+SHH cards mounted and tested. Dark current
measured.

EML3A07: Pressured to 3 bar and leak rate will be measured. Received
parts for gluing on the survey target. I am contacting Ed about how to
glue the missing parts to be glued on.

EMS5C08: Opened crate and started apply epoxy to all tubelets. 

3) Chambers in hospital 

none

4) Other issues:  

- Space for UW.  Half of the planned space for them has been ready.

- Joerg discussed with me about filling DB for logistics. I think it's
good to do so so that one can track where our chamber will be from
internet. I agreed to do so once he opens an account for us.

- Two summer students joined us: Pierre Cornell and Ezra Levin.  We
expect that the production rate to ramp up.

Zhenngguo Zhao