Michigan B184 Update July 30, 2004

Back to B184 updates * Previous * Next


1) Chambers passing CR test
 
  a) Chambers passing CR test this week:  EMS4A14, EML4C01, EMS5C14 

    EMS5C14 needs a more detailed data check.  This chamber has had
    applied epoxy to all endplugs between Al ring and endplug location
    and the leak rates are 3.2 and 1.0 mbar/day for He at 3 bars.
    This chamber also has problem of high dark current of over microA.
    After cleaning three times with alcohol the dark current went back
    to normal.  As I reported before, I suspect that snoop was used on
    some of the tubes (in 2002).

  b) Total number of chamber passed CR test at CERN:   44
 
2) Chambers in progress
 
  EMS4C08: Will be ready for CR test today 
  EMS4C14: Will be ready for CR test today, or next Monday
  EMS4A16: Ready for dark current test
  EMS5C10: Bottom multilayer has high dark current and we are dealing with it.
  EMS5A04: Failed long term gas leak tightness. Recertify with helium.

3) Chambers in hospital - none

4) Problems and other issues

  We no longer use the spreader bar to lift our chambers.  We simply
  use a very long sling (attached directly to the rotator frame) which
  plays the same role as a spreader bar, and is as safe.
 
  All contents from the shipment to bldg184 have arrived in bldg184.
  We're now unloading everything and I have to stop here to deal with
  this.

Zhengguo Zhao