MDT Endcap files for MTF Database |
| CSM/DCS serial number files: | SN_MTF1.txt (revised Feb 9, 2006) |
| SN_MTF2.txt (July 27, 2006) | |
| SN_README.txt | SN_MTF_FINAL1.txt (Jan 30, 2007) EIL4, EMS, EML |
| SN_MTF_FINAL2.txt (Feb 6, 2007) EOS, EOL | |
| Mezanine card serial number files: | MEZZSN_MTF1.txt (revised Feb 9, 2006) |
| MEZZSN_MTF2.txt (July 18, 2006) | |
| MEZZSN_README.txt | MEZZSN_MTF_FINAL1.txt (Feb 6, 2007) EIL4, EMS, EML |
| MEZZSN_MTF_FINAL2.txt (Feb 6, 2007) EOS, EOL | |
| HVHH card serial number files: | HVHH_MTF1.txt (updated Feb 7, 2006) |
| HVHH_MTF2.txt (updated May 15, 2006) | |
| HH_README.txt | HVHH_MTF_FINAL1.txt (Feb 1, 2007) EIL4, EMS, EML |
| HVHH_MTF_FINAL2.txt (Feb 6, 2007) EOS, EOL | |
| ROHH card serial number files: | ROHH_MTF1.txt (updated Feb 7, 2006) |
| ROHH_MTF2.txt (updated May 15, 2006) | |
| HH_README.txt | ROHH_MTF_FINAL1.txt (Feb 1, 2007) EIL4, EMS, EML |
| ROHH_MTF_FINAL2.txt (Feb 6, 2007) EOS, EOL | |
| Temperature sensor files: | TSENSOR_MTF1.txt |
| TSENSOR_MTF2.txt
Dec 11, 2006 Replaces old version below - has correct locations |
|
|
incorrect version - sensor
locations were wrong
|
|
|
TSENSOR_MTF_FINAL1.txt (Mar 8, 2007)
EM, EIL4 Washington Tsensors |
|
| Magnetic Field sensor files: | BSENSOR_MTF1.txt (revised Feb 28, 2006) |
| BSENSOR_MTF2.txt (July 18, 2006) |
| IDMechPar | = Chamber name |
| MDT_ID | = MDTSerialNumber, e.g. ATLM.M.EML.1C03 |
| CSM_MB | = CSM Motherboard Serial Number e.g EU-MB-04-20-0160 |
| CSM_ID | = CSM Serial Number e.g US-CSM-04-11-0187 |
| DCS_NODE | = DCS node number |
| NIKHEF_ID | = DCS Nikhef ID, e.g. D028e |
| BarCode | = DCS barcode e.g. 20MMFIAD001289 |
| = Calibration constant 1 (offset) |
| IDMechPar | = Chamber name |
| Mezz_ID | = Mezz card serial number |
| ML | = Multilayer [1:2] |
| STEP | = Position of card on ML in order of increasing chamber Z coordinate. [1:N] |
| CSM_CH | = Readout channel on CSM card |
| CABLE_LEN | = Length of CSM cable in cm |
| IDMechPar | = Chamber name |
| ID | = HVHH ID number |
| ML | = Multilayer [1:2] |
| STEP | = Position of card on ML in order of increasing chamber Z coordinate. [1:N] |
| TYPE | = Type of card (layout) [1:2] |
| CSM_CH | = Readout channel on CSM card |
| IDMechPar | = Chamber name |
| ID | = Sensor ID number |
| Type | = 1=>Washington Tsensor 2=>Brandeis Tsensor |
| Channel | = Readout channel |
| Location | = Location on chamber (number to be defined on a diagram) |
| Const1 | = Calibration constant 1 (offset) |
| Const2 | = Calibration constant 2 (slope) |
| Flag | = bit flag of sensor status |
| IDMechPar | = Chamber name |
| ID | = Sensor ID number (8 digit hex number) |
| Channel | = Readout channel [0:3] |
| Location | = Location on chamber (defined on Brandeis chamber diagrams) |
| Orientation | = Sensor orientation [-1,1] |